Insulation support anchor A2 Stainless ISA-S 80/40

https://certifix.co.uk/web/image/product.template/7764/image_1920?unique=9a7bbe5

£ 144.64 £ 144.64 144.64000000000001 GBP / 250

£ 153.93 / 250 not combination_info.get('is_rental')

  • Drill Hole Depth
  • Embedment Depth
  • Max. Thickness
  • Material
  • Head Diameter

This combination does not exist.

For insulation up to 40mm, Length 80mm, Drill Hole Depth 45mm, Embedment Depth 40mm, Head Diameter 35mm


Available Stock: 19.00 x 250
Incl. Future Stock: 19.00 x 250
Drill Hole Depth: 45mm
Embedment Depth: 40mm
Max. Thickness: 40mm
Material: A2 stainless steel
Head Diameter: 35mm

Unit of Measure Name: 250
Internal Reference: ISA2-80
Technical Datasheet:
Shipment: Shipped from our warehouse

 NEED INFO / PRICING?
 0161 672 3333 
 


Terms & Conditions

Insulating anchor for cold-, heat- and fire-protection


The A2 or Zinc-Plated fire rated insulation support anchor. Simply hammer the anchor into the prepositioned insulation, and the anchor will expand into the substrate, securing the load. The hammer

installation allows fast setting and reducing the amount of work. 

Features
  • Approved for multiple fastenings of insulation panels
  • High load-bearing capacity in cracked and non-cracked concrete
  • Small drill holes
  • Can be coated to any colour within around 5 – 10 working days
  • Quick and safe installation



  • Approved for C20/25 – C50/60 concrete
  • Approval in both cracked and non-cracked concrete



The fire rated insulation support anchor available in either A2 Stainless and Zinc-Plated Steel. Simply hammer the anchor into the pre-positioned insulation, and the anchor will expand into the substrate, securing the load. The hammer installation allows fast setting and reducing the amount of work.

  • Approved for C20/25 – C50/60 concrete
  • Approval in both cracked and non-cracked concrete
  • Approved for multiple fastenings of insulation panels
  • High load-bearing capacity in cracked and non-cracked concrete
  • Small drill holes
  • Quick and safe installation

Technical Characteristics Without Fire Exposure

ISA-S / ISA-Z Insulation Anchor

Drill Bit Diameter

d0

[mm]

8

Depth of Drill Hole

h1         ≥

[mm]

45

Effective Anchorage Depth

hef        ≥

[mm]

40

Minimum Thickness of Member

hmin

[mm]

80

Edge Distance

c

[mm]

60

Spacing

s

[mm]

120

Permissible load in cracked and non-cracked concrete C20/25 – C50/60¹ʾ²ʾ

Nzul

[kN]

0.074

The partial safety factor for material resistance from the approval yM = 1.5 as well a partial safety factor for load actions yF = 1.4 were considered for determining the load

Technical Characteristics Under Fire Exposure

ISA-S / ISA-Z Insulation Anchor

Fire Resistance Class

R 30

Permissible Load Ffi,per,30 1)

[kN]

0.09

R 60

Permissible Load Ffi,per,60 1)

[kN]

0.09

R 90

Permissible Load Ffi,per,90 1)

[kN]

0.09

R 120

Permissible Load Ffi,per,120 1)

[kN]

0.09

R 180

Permissible Load Ffi,per,180 1)

[kN]

0.06

R 30 – R 120

Spacing sfi 

Edge Distance cfi

[mm]

120

 The partial safety factor for material resistance from the approval yM = 1.0 as well a partial safety factor for load actions yF = 1.0 were considered for determining the load.

Installation Instructions

Installation Instructions

  1. Set drill hole
  2. Clean out drill hole from the base
  3. Knock insulation fastener through the insulation panel with a hammer
  4. Anchor disc must fully contact the insulation panel

Minimum 4 anchors per square meter for insulation panel. The dimension between axes and edge distance is valid without fire exposure. Assumed that an application is forced with fire exposure.

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.