    Description

    Certifix CFCS is a high performance, highly versatile concrete screw, ideally suited for use on Rainscreen Cladding but also for use helping fasten hand brackets, fire barrier brackets, high racking, safety rails, metal profiles, base plates and consoles. Available in both A4 Stainless and Zinc-Plated steel, Certifix CFCS Concrete Screws feature a saw tooth geometry, making them perfect for a quick and easy installation and eliminating the need to clean the drill hole for installation in ceilings and walls.

    Product Features

      Saw tooth geometry: Quick, safe and easy installation.
     Available in stainless steel A4 and HCR:  Ideal for use in reinforced and unreinforced normal concrete and in cracked and non-cracked concrete
     Available in zinc-coated steel, tested to DIN EN ISO 9227 – for corrosion category C5 – 4800hrs
     Can be loaded immediately, with adjustment possible: Time saving.
     Fire rated and ETA approved: Pedigree.

    Hex Washer Head

    Suitable for helping hand bracket fixings – the washer head gives increase surface area, this is improved with a CFCS A4 washer which stops the brackets spinning on installation, and also gives more surface area for the concrete screw to press against on installation.
    Suitable for fire barrier fixings – no washer recommended for this application. 
    Suitable for some type of U Channel.

    Materials

     Zinc Flake Steel
     Zinc Plated Steel
     Zinc Coating for category C5 - 4800hrs (Corrosivity Tested on CFCS 8+)
     A4 Stainless Steel
     HCR Stainless Steel

     Helping hand brackets into substrate
    • Where post install checks are required
    • Fire barrier brackets into substrate
    • Railing systems for bridge construction
    • High racking
    • Safety rails into substrate
    • Metal profiles into substrate
    • U Channel into substrate*
    • Base plates/consoles into substrate
    • Fastening of facade panels back to concrete reveals*

      *Please check our head type


    Single Fastening Without Fire Exposure

    1) The partial safety factor for material resistance from the approval γM=1,5 as well a partial safety factor for load actions γF=1,4 were considered for determining the load.

    2) These values apply without influence of the spacing and edge distances
    3) C2 only for version zinc plated

    Single Fastening With Fire Exposure

    1) The partial safety factor for material resistance from the approval γM=1,0 as well a partial safety factor for load actions γF=1,0 were considered for determining the load.

    Multiple Fastening Without Fire Exposure

    1)  The partial safety factor for material resistance from the approval γM=1,5 as well a partial safety factor for load actions γF=1,4 were considered for determining the load.

    2) These values apply without influence of the spacing and edge distances.

    Multiple Fastening With Fire Exposure

    1) The partial safety factor for material resistance from the approval γM=1,0 as well a partial safety factor for load actions γF=1,0 were considered for determining the load.

     

    FOR MORE IN DEPTH TECHNICAL DATA AND INSTALLATION PLEASE DOWNLOAD OUR TECHNICAL DATA SHEET

    Similar Products

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.