{"product_id":"pull-out-test-england-wales","title":"Pull Out Test (England \u0026 Wales)","description":"We offer both preliminary and post-installation tests:\n\nFor preliminary tests, we carry out preliminary checks on a selection of anchors, starting from the most cost effective or as per client’s preference. Once one of these produces a satisfactory result, we will test 5no. of the same anchor to validate a consistent performance into the substrate.\n\nPost-installation proof tests can be carried out to validate the quality of the installation prior to the cladding rails \u0026amp; panels being installed. Our testing is usually chargeable with a daily fee. According to BS8539:2012, testing should occur on 2.5% of anchors, unless there is a failure, if so the percentage increases to 5%. If there is a further failure, 100% of the anchors must be tested. Due to the uncertain nature of the quantity of tests \u0026amp; man hours required for each project, as it depends on the quality of installation which is outside of our control, we offer a daily rate instead of a fixed fee \/ build in cost.","brand":"Certifix","offers":[{"title":"Default Title","offer_id":51279169487012,"sku":"26251","price":750.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/4496\/1700\/files\/pull_test2.jpg?v=1773977715","url":"https:\/\/certifix.co.uk\/products\/pull-out-test-england-wales","provider":"Certifix","version":"1.0","type":"link"}